Model IA Analog Electronic Potential Meter
For Electrolysis, Corrosion and Cathodic Protection Testing
The Model IA Analog meter is designed for use
by non-technical personnel including crews, servicemen, meter
readers, etc., but it is also suitable for the most experienced
engineers and technicians.
10 megohm input resistance practically eliminates low potential readings
caused by resistance in the external circuit due to contact
resistance of the reference electrode. This condition is frequently encountered in
city work and in frozen ground.
- Low cost
- Rugged
- Easy-to-use
- Structure to earth potentials
- 0 - 2 volts or go-no-go
- Includes electrode and two leads
- Optional electrode extension
Specifications:
- 2½" taut-band rugged instrument.
- Weatherproofed neoprene gasket.
- 10 MΩ input resistance.
- Solid-state impedance amplifier.
- Operates on one small 9 V transistor battery, low drain - long
shelf life, push switch to check battery condition, battery easily replaced and readily
available.
- Push switch to read potentials, current drain only while taking
readings.
- Scale marked 0VDC to 2VDC, color band: Red to 0.85VDC, Green to 2VDC.
- Filter eliminates errors caused by AC, Up to 50 volts 50/60 Hz.
- Operating temperature: 0oF to 150oF.
- Molded PVC housing.
- Plastic carrying case with resilient padding.
- Modular construction
- Weight: about 3 lbs.
- Size: 2 ½" deep x 10" long.
Ordering Information:
Model IA (Cat. #4107) includes potential meter, RE-5 CuSO4
electrode, one 8' test lead with large clip attached, one 8' test
lead with 27-C test clip, battery, top and bottom protective covers,
and carrying case. Shipped assembled in case.
Warranty: Any part which fails during first year (except battery) will be
repaired or replaced by M. C. Miller Co., Inc. without charge, when returned to M. C. Miller
Co., Inc. prepaid and insured.